Bug 3950

Summary: Don't always call dbus_shutdown in SDL_DBus
Product: SDL Reporter: Alexander Larsson <alexl>
Component: *don't know*Assignee: Ryan C. Gordon <icculus>
Status: RESOLVED FIXED QA Contact: Sam Lantinga <slouken>
Severity: normal    
Priority: P2 CC: sezeroz
Version: HG 2.1   
Hardware: x86_64   
OS: Linux   

Description Alexander Larsson 2017-11-09 08:38:11 UTC
dbus_shutdown() is a debug feature which closes all global resources in the dbus library. Calling this should be done by the app, not a library, because if there are multiple users of dbus in the process then SDL could shut it down even though another part is using it.

For example, i had an issue with this in mGBA, which uses both Qt and SDL, both using libdbus. I had a session bus, but no system bus (this was in a flatpak sandbox), and when SDL_DBus_Init() failed to init the system bus it called dbus_shudown() and continued on. This caused issues for Qt when running due to its session bus connections having disappeared beneath it.
Comment 1 Sam Lantinga 2018-02-13 16:08:10 UTC
Fixed, thanks!
https://hg.libsdl.org/SDL/rev/5ec7bc5b3d12